Title
Mfr/Vendor
Stock # 
Voltage, Input
(V )
Frequency
(Hz)
Fuse Type
Dielectric Test Mode Output RatingAC
(Kv )
Dielectric Test Mode Output RatingDC
(Kv )
Ramp HI
(mA )
Ramp TimerAC
(sec )
Ramp TimerDC
(sec )
Charge Low
(uA )
Current Display RangeAC
(mA )
Current Display RangeDC
(uA )
High LimitAC
(mA )
High LimitDC
(uA )
Low LimitAC
(mA )
Low LimitDC
(uA )
DC Output Ripple
(% )
Discharge Time
(mS )
Dwell TimerAC
(sec )
Dwell TimerDC
(sec )
Ground Continuity
(Amp )
Continuity Test Mode Hi-Low Limit
(ohms )
Continuity Test Mode Resistance Display
(ohms )
DUT VoltageAC
(V )
DUT CurrentAC
(Amp )
DUT Short Circuit ProtectionAC
(Amp )
IR Short Current
(mA )
IR Resistance Display
(MOhms )
IR Voltage
(V DC )
Leakage Current Display
(uA )
Trip Point Settings, CurrentAC
(Amp )
Trip Point Settings, Leakage Current
(mA )
Trip Point Settings, Power Factor
Trip Point Settings, Voltage
(V AC )
Trip Point Settings, Watts
(W )
DUT Voltage Display
(V )
Leakage Current Display, Range 1
(uA )
Leakage Current Display, Range 2
(uA )
Leakage Current Display, Range 3
(uA )
MD Voltage Limit
(V )
Delay Timer
(sec )
Title: Electrical Safety, AC/DC Hipot, IR, Functional Run, Line Leakage & Ground Bond Tester: OMNIA® 8100 Series (6 in 1)
Electrical Safety, AC/DC Hipot, IR, Functional Run, Line Leakage & Ground Bond Tester: OMNIA® 8100 Series (6 in 1) Associated Research - Electrical Safety Compliance Testing Instruments, Hiport Testers, Ground Bond 8106 115/230 50/60 6.3A slo blo 5 @ 40mA 5 @ 20mA 20 peak max 0.1 Up, 00 Down - 999.9 0.4 Up, 0.0,10 Down - 999.9 0-350 or Auto Set 0-40 0-20,000 0-40 0-20,000 0-40 0-20000 <4 <200 0, 0.4-999.9 0.3-999.9 DC 0.1+/- 0.01 Fixed 0-10 0-10 0-277 15 23 >20 Peak 0.05-50000 50-1000 0-6,000 0.1-15 0-10 0-1 0-277 0-4200            
Title: Electrical Safety, Line Leakage Tester (stand alone): LINECHECK®
Electrical Safety, Line Leakage Tester (stand alone): LINECHECK® Associated Research - Electrical Safety Compliance Testing Instruments, Hiport Testers, Ground Bond 510L 115/230 47/63 2A slo blo                   0-6000   0-6000               30-300 30 32                   30-300 0.0-29.9 30-999.9 1000-6000 20 0.0, 1.0-999.9
Title: Electrical Safety, Line Leakage Tester (w/ built in switching): LINECHECK®
Electrical Safety, Line Leakage Tester (w/ built in switching): LINECHECK® Associated Research - Electrical Safety Compliance Testing Instruments, Hiport Testers, Ground Bond 520L 115/230 47/63 2A slo blo                   0-6000   0-6000               30-300 10 11                   30-300 0.0-29.9 30-999.9 1000-6000 20 0.0, 1.0-999.9