Associated Research - Electrical Safety Compliance Testing Instruments, Hiport Testers, Ground Bond Company Profile
Associated Research - Electrical Safety Compliance Testing Instruments, Hiport Testers, Ground Bond
Private Ownership
13860 W. Laurel Dr.
Lake Forest, IL 60045 USA

Phone: 847.367.4077
Fax: 847.367.4080
Tollfree: 800.858.8378

www.asresearch.com

Electrical Safety, AC/DC Hipot, IRTester w/ enhanced graphic LCD: HypotULTRA III


  • HypotULTRA® III, model 7650, is a 3-in-1 dielectric analyzer with an enhanced graphic LCD and analog bar graph
  • HypotULTRA® III provides AC/DC Hipot and Insulation Resistance testing
  • Able to perform point-to-point continuity and hipot tests at voltages up to 5,000 volts with one set of test connections
  • Can be used as a bench top instrument or as a PC controlled system used in tandem with our stand alone Autoware® control software
  • Extended test capability is provided with the optional 4 or 8 port built-in scanning matrix and the 2K Ohm continuity test mode
  • The ability to perform multiple tests with a single connection will increase production and efficiency while saving time and money
  • The enhanced graphic greatly simplifies the user interface and makes testing safer, easier and more reliable than ever before.

  • Dimensions: 16.9x3.5x19.7
  • Mechanical Bench or Rack Mount
  • Serial Interface: RS-232, GPIB or Printer Interface
  • UL and TUV Safety Agency Listed
  • SmartGFI® Safety Circuit

  • Capacitive Load: 1uF <1kV, 0.75uF <2kV, 0.50uF <3kV, 008uF <4kV, 0.04uF <5kV

    Standard Items: Owner's Manual, Cable Assembly Return, Hipot Lead, Interlock Connector, Fuse 4A 250V SB, Rack Mount Bracket and Handle
    Optional Items: Return Retractable Probe, Safe-T Probe, Interlock Connector, Receptacle Adapter Box HV, Adjustable Resistor Bank,
    Hipot Retract Probe, 4 or 8 Port Scanner
    More Product Info and Specifications

  • Customize your results in the table below... Reset Table
    Filter Products : Sort Products :

      No filters available
          First by     
          Then by     
       

    Showing 1 through 1 of 1 items
    Stock #
    Voltage, Input
    (V )
    Frequency
    (Hz)
    Fuse Type
    Dielectric Test Mode Output RatingAC
    (Kv )
    Dielectric Test Mode Output RatingDC
    (Kv )
    Dielectric Test Mode Voltage Display
    (Kv )
    Ramp HI
    (mA )
    Ramp TimerAC
    (sec )
    Ramp TimerDC
    (sec )
    Charge Low
    (uA )
    Current Display RangeDC
    (uA )
    High LimitAC
    (mA )
    High LimitDC
    (uA )
    Low LimitAC
    (mA )
    Low LimitDC
    (uA )
    DC Output Ripple
    (% )
    Discharge Time
    (mS )
    Dwell TimerAC
    (sec )
    Ground Continuity
    (Amp )
    Continuity Test Mode Hi-Low Limit
    (ohms )
    Continuity Test Mode Resistance Display
    (ohms )
    IR Short Current
    (mA )
    IR Resistance Display
    (MOhms )
    IR Voltage
    (V DC )
    7650 115/230 50/60 4A slo blo 5 @ 30mA 5 @ 10mA 0-5 AC 12 peak max (DC) 0.0-999.9 0.0, 0.1-999.9 0-350 or Auto Set 0-9.99 (ma) 0-30 0-10000 0-30 0-10000 <4 <200 0.0, 0.4-999.9 DC 0.1+/- 0.01 Fixed 0.0-2000 0.0-2000 12 peak 0.05-50000 50-1000