Company Profile
TASI Group - AW Lake Monitor, KEM Kueppers - Positive Displacement Flow Meter Mass Coriolis Private Ownership 8809 Industrial Dr Franksville, WI 53126 USA
Phone: 262.884.9800 Fax: 262.884.9810
www.awcompany.com
|
| Helical Gear, Positive Displacement Flow Meters, SRZ Series |
 |
-
Applications: adhesives,
sealants, epoxies, resin, polyurethanes, PVC's and filled fluids.
Helical Gear Design
Flow range from 0.003 to 105 gpm
Accuracy to ± 0.25% of reading
Wetted parts: stainless steel, tungsten
carbide, Teflon®
6,000 psi pressure rating
Ideal meter for filled
fluids
|
|
Two highly accurate
cycloid-shaped screw spindles mesh and rotate inside a cylindrical housing
with two overlapping holes in the form of a figure 8. The medium flows in
an axial direction rotating the spindles without pulsation. The speed of
the spindles is proportional to the flow rate over a 1:100 turn down
ratio.
Specifications:
-
100:1 Turndown Ratio.
-
Factory calibration
provided.
-
Handles varying conditions
of viscosity, temperature & flow without linearization.
-
Precision machined,
surface hardened, stainless steel helical rotors.
-
Maintains highly accurate
measurements over entire flow range.
-
303/321 Stainless Steel
used throughout.
-
Compact, rugged, high
pressure design.
Technical Data:
-
Accuracy: ±0.5% above
30cSt, ±0.25% above 100cSt
-
Repeatability: ±0.1%
-
Temperature: 300°F
(Higher temperatures upon request)
-
O-ring Seal Material:
Teflon/Viton optional
|
|
|
Pickup Sensor Options:
VTER/P |
Pickup Sensor Options:
VTER |
Pickup Sensor Options:
CAPM-20 KEM |
-
Standard sensor
-
5 pin screw-on connector
-
Fluid temp to 250°F
-
Long version to 300°F
-
7-29vdc
|
|
-
3 pin screw-on connector
-
Intrinsically safe
-
UL approved
-
Fluid temp to 185°F
-
10-30vdc
|
|
|