absolute measuring range: 0.03 up to 0.8 ltr./min
-
linear measuring range: 0.05 up to 0.8 ltr./min
-
measuring media: fluids without contamination
-
filters: 20 to 40 micron necessary
-
viscosity range: up to approx. 15 mm²/sec
-
linearity: ±2.5% of actual flow
-
depending on viscosity variations
-
repeatability: better than 0.5%
-
pulse rate: approx. 139,000 pulses/litre, see diagram
below
-
pressure drop: depending on viscosity, see diagram
below
-
operating temperature: _20 up to +180°C for standard
versions
-
operating pressure: up to 640 bar with Ermeto
connections
-
tube fittings: Ermeto threads type m14s for tube 14 x
4 mm or flanges dia 15
-
overall length: 68 mm
-
materials: stainless steel as per DIN 1.4305, 1.4122
(cf. AISI 303) on request 1.4571, 1.4460 (cf. AISI 316 Ti and 329)
sapphire bearings