TASI Group - AW Lake Monitor, KEM Kueppers - Positive Displacement Flow Meter Mass Coriolis Company Profile
TASI Group - AW Lake Monitor, KEM Kueppers - Positive Displacement Flow Meter Mass Coriolis
Private Ownership
8809 Industrial Dr
Franksville, WI 53126 USA

Phone: 262.884.9800
Fax: 262.884.9810

www.awcompany.com

Meter Mounted Flow Monitor, RT-Ex3

The RT-Ex3 is a meter-mounted digital flow monitor housed in a Class I Hazardous Location Rated Enclosure. A large, back-lighted LCD graphic display provides easy to read indication of flow rate or total in user programmable engineering units. Change of display modes or reset of the totalizer is accomplished using an attached magnet without opening the enclosure. An isolated input also allows for remote reset of the totalizer. Programmable opto-isolated open-collector outputs provide flowrate limit indication or a pulsed total output for remote monitoring and recording of totals. A 4-20 mA rate output with user programmable filtering and scaling is also provided for remote rate indication and 24 VDC power is required. The RT-EX3 is compatible with all AW Company JVM and JV-KL Series flow meters.

Specifications

  • Digital meter mounted flow monitor

  • Programmable outputs

  • 4-20mA rate output

  • For hazardous locations

  • Scaled pulse output ·Multiple display modes

  • Large LCD graphic display

  • Magnetically select rate, total or reset

 

Technical Data

Power Requirement: 24 VDC/500mA. (customer supplied)

Analog Output 4-20 mA:

  • 12-bit D/A Converter

  • Internal Powered Loop Output.

  • Max. Load Impedance: 500 ohm.

Enclosure Certifications:

  • Class I, Groups B, C, D

  • Class II, Groups E, F, G

  • Class III

  • Cenelec: EEx d IIC, IP66

  • NEMA 4X, 7BCD, 9EFG

  • CSA Certified Standard C22.2-30

  • FM Class No. 3615

  • INIEX Cert. Rating EX88B103703U

  • ISSEP CENELEC Standard EN 50014,50018

Sensor/Monitor Frequency Range: 0-4000 Hz

Temperature Ratings: -20 to 85ºC (-4 to 185ºF)

Device Certification: EPSILON LTD. CENELEC EEx dm IIC, T6, Standard EN 50014,50018, & 50028

Connection: Labeled Pigtail Leads, ½" NPT Conduit Provisions

Two Opto-Isolated Open-Collector Outputs: 5-30 VDC Rating, 50 mA Max. (Minimum Load Impedance Required, 600 Ohm @ 30 VDC)

Opto-Isolated Reset Input: 5-30 VDC Input, 3.3Kohm Impedance