Global Business Directory

Search for: Products & Services Company Name
 
 


Vaisala Inc - Scientific Weather Monitoring Instruments Dewpoint Humidity CO2 Barometric Pressure Company Profile
Vaisala Inc - Scientific Weather Monitoring Instruments Dewpoint Humidity CO2 Barometric Pressure
Stock Symbol VAIAS (Helsinki)
Vanha Nurmijarventie 21
Vantaa 01670 Finland

Phone: 358 9 894 91
Fax: 358 9 8949 2227

www.vaisala.com

Humidity and Temperature Transmitter, HMP 233 w/ Compact 120 Deg C Probe, Metric Display
The microprocessor-based HMP230 Series products are versatile and easy to use transmitters
for demanding industrial and air conditioning applications. The transmitters measure relative
humidity and temperature. As calculated variables they also output dewpoint and wet bulb
temperature, mixing ratio and absolute humidity. The HMP230 Series Transmitters can be
configured to the customer's requirements on the production line, but configuration and parameters
can also be set by the user. Both analogue and serial outputs are available as well as several options:
different cable lengths, power supply modules, serial interface modules and a local display.








Product Configuration (Example Stock #) HMP233-A-1-A-0-A-2-x-xx-y-yy-z-1-A-3-A

where 0 = Power Supply, Alarm Output, and Connector Options
where x = Analog Output Signal Channel 1
where xx = Analog Output Signal Channel 2
where y = Analog Output Parameters Channel 1
where yy = Analog Output Parameters 2
where z = Analog Output Temperature Range

The last number in the stock number represents the regaining options
Use the number three (3) for no re-gain; the number two (2) for re-gain option

The last letter in the stock number represents the manual options
Manual options include A (no manual) B (English) C (German) D (French) E Finnish


Replace x, xx, y, yy and z with one of the following values:

Power Supply, Alarm Output, Connector Options Analog Output Signal Channel 1(x) Analog Output Signal Channel 2 (xx) Analog Output Parameters Channel 1 (y) Analog Output Parameters Channel 2 (yy) Analog Output Temperature Ranges (z)
0= 24V, No Connectors A= 4...20mA A= 4...20mA 1= RH 0...100% 1= RH 0...100% A= -20 to +80 C.
1= 115V, No Connectors B= 0...20mA B= 0...20mA 2= T Temperature range 2= T Temperature range B= -20 to +120 C.
2= 230V, No Connectors C= 0...1 V C= 0...1 V 3= Td= -40 to +100 C. 3= Td= -40 to +100 C. C= -40 to +80 C.
3= 24V, + alarm output unit, no connectors D= 0...5 V D= 0...5 V 4= a= 0...600 g/m3 4= a= 0...600 g/m3 D= -40 to +120 C.
4= 24V shared connector for power supply and analog outputs E= 0...10 V E= 0...10 V 5= Tw= 0 to +100 C. 5= Tw= 0 to +100 C. E= -40 to +60 C.
5= 24V shared connector for power supply and analog outputs +alarm output * * 6= x= 0...500 g/kg d.a. 6= x= 0...500 g/kg d.a. F= 0 to +100 C.
6= 115 V connector for analog outputs * * 7= h= -40 to +1500 kJ/kg 7= h= -40 to +1500 kJ/kg *
7= 230 V connector for analog outputs * * * * *
8= 24V connector for RS 232C * * * * *
9= 24V connector for RS 232C/485/422+ analog output & power supply * * * * *

Customize your results in the table below... Reset Table
Filter Products : Sort Products :
      Serial Interface  
      Transmitter Type  
      Installation Kit  
      Length (Probe Cable) (mm ) 
      First by     
      Then by     
   

Showing 1 through 30 of 90 items   |   Next page
Stock #
Serial Interface
Transmitter Display
Sensor Protection (Transmitter)
Analog Output Signal (Channel 1)
Analog Output Signal (Channel 2)
Transmitter Type
Analog Outupt Parameters (Channel 1)
Analog Outupt Parameters (Channel 2)
Installation Kit
Length (Probe Cable)
(mm )
HMP233-A-1-F-0-A-2-x-xx-y-yy-z-1-A-3-A RS 232C Metric PPS Plastic Grid and SS Netting X XX RH+T Y YY None 10, 120 Deg C
HMP233-A-1-F-0-B-2-x-xx-y-yy-z-1-A-3-A RS 485/RS 422 Metric PPS Plastic Grid and SS Netting X XX RH+T Y YY None 10, 120 Deg C
HMP233-A-1-F-0-C-2-x-xx-y-yy-z-1-A-3-A Current Loop Metric PPS Plastic Grid and SS Netting X XX RH+T Y YY None 10, 120 Deg C
HMP233-A-1-F-0-A-2-x-xx-y-yy-z-1-C-3-A RS 232C Metric PPS Plastic Grid and SS Netting X XX RH+T Y YY Duct Mounting 10, 120 Deg C
HMP233-A-1-F-0-B-2-x-xx-y-yy-z-1-C-3-A RS 485/RS 422 Metric PPS Plastic Grid and SS Netting X XX RH+T Y YY Duct Mounting 10, 120 Deg C
HMP233-A-1-F-0-C-2-x-xx-y-yy-z-1-C-3-A Current Loop Metric PPS Plastic Grid and SS Netting X XX RH+T Y YY Duct Mounting 10, 120 Deg C
HMP233-C-1-F-0-A-2-x-xx-y-yy-z-1-A-3-A RS 232C Metric PPS Plastic Grid and SS Netting X XX RH+T+a+Tw+x Y YY None 10, 120 Deg C
HMP233-C-1-F-0-B-2-x-xx-y-yy-z-1-A-3-A RS 485/RS 422 Metric PPS Plastic Grid and SS Netting X XX RH+T+a+Tw+x Y YY None 10, 120 Deg C
HMP233-C-1-F-0-C-2-x-xx-y-yy-z-1-A-3-A Current Loop Metric PPS Plastic Grid and SS Netting X XX RH+T+a+Tw+x Y YY None 10, 120 Deg C
HMP233-C-1-F-0-A-2-x-xx-y-yy-z-1-C-3-A RS 232C Metric PPS Plastic Grid and SS Netting X XX RH+T+a+Tw+x Y YY Duct Mounting 10, 120 Deg C
HMP233-C-1-F-0-B-2-x-xx-y-yy-z-1-C-3-A RS 485/RS 422 Metric PPS Plastic Grid and SS Netting X XX RH+T+a+Tw+x Y YY Duct Mounting 10, 120 Deg C
HMP233-C-1-F-0-C-2-x-xx-y-yy-z-1-C-3-A Current Loop Metric PPS Plastic Grid and SS Netting X XX RH+T+a+Tw+x Y YY Duct Mounting 10, 120 Deg C
HMP233-F-1-F-0-A-2-x-xx-y-yy-z-1-A-3-A RS 232C Metric PPS Plastic Grid and SS Netting X XX RH+T+h Y YY None 10, 120 Deg C
HMP233-F-1-F-0-B-2-x-xx-y-yy-z-1-A-3-A RS 485/RS 422 Metric PPS Plastic Grid and SS Netting X XX RH+T+h Y YY None 10, 120 Deg C
HMP233-F-1-F-0-C-2-x-xx-y-yy-z-1-A-3-A Current Loop Metric PPS Plastic Grid and SS Netting X XX RH+T+h Y YY None 10, 120 Deg C
HMP233-F-1-F-0-A-2-x-xx-y-yy-z-1-C-3-A RS 232C Metric PPS Plastic Grid and SS Netting X XX RH+T+h Y YY Duct Mounting 10, 120 Deg C
HMP233-F-1-F-0-B-2-x-xx-y-yy-z-1-C-3-A RS 485/RS 422 Metric PPS Plastic Grid and SS Netting X XX RH+T+h Y YY Duct Mounting 10, 120 Deg C
HMP233-F-1-F-0-C-2-x-xx-y-yy-z-1-C-3-A Current Loop Metric PPS Plastic Grid and SS Netting X XX RH+T+h Y YY Duct Mounting 10, 120 Deg C
HMP233-B-1-F-0-A-2-x-xx-y-yy-z-1-A-3-A RS 232C Metric PPS Plastic Grid and SS Netting X XX RH+T+Td Y YY None 10, 120 Deg C
HMP233-B-1-F-0-B-2-x-xx-y-yy-z-1-A-3-A RS 485/RS 422 Metric PPS Plastic Grid and SS Netting X XX RH+T+Td Y YY None 10, 120 Deg C
HMP233-B-1-F-0-C-2-x-xx-y-yy-z-1-A-3-A Current Loop Metric PPS Plastic Grid and SS Netting X XX RH+T+Td Y YY None 10, 120 Deg C
HMP233-B-1-F-0-A-2-x-xx-y-yy-z-1-C-3-A RS 232C Metric PPS Plastic Grid and SS Netting X XX RH+T+Td Y YY Duct Mounting 10, 120 Deg C
HMP233-B-1-F-0-B-2-x-xx-y-yy-z-1-C-3-A RS 485/RS 422 Metric PPS Plastic Grid and SS Netting X XX RH+T+Td Y YY Duct Mounting 10, 120 Deg C
HMP233-B-1-F-0-C-2-x-xx-y-yy-z-1-C-3-A Current Loop Metric PPS Plastic Grid and SS Netting X XX RH+T+Td Y YY Duct Mounting 10, 120 Deg C
HMP233-D-1-F-0-A-2-x-xx-y-yy-z-1-A-3-A RS 232C Metric PPS Plastic Grid and SS Netting X XX RH+T+Td+a+Tw+x+h Y YY None 10, 120 Deg C
HMP233-D-1-F-0-B-2-x-xx-y-yy-z-1-A-3-A RS 485/RS 422 Metric PPS Plastic Grid and SS Netting X XX RH+T+Td+a+Tw+x+h Y YY None 10, 120 Deg C
HMP233-D-1-F-0-C-2-x-xx-y-yy-z-1-A-3-A Current Loop Metric PPS Plastic Grid and SS Netting X XX RH+T+Td+a+Tw+x+h Y YY None 10, 120 Deg C
HMP233-D-1-F-0-A-2-x-xx-y-yy-z-1-C-3-A RS 232C Metric PPS Plastic Grid and SS Netting X XX RH+T+Td+a+Tw+x+h Y YY Duct Mounting 10, 120 Deg C
HMP233-D-1-F-0-B-2-x-xx-y-yy-z-1-C-3-A RS 485/RS 422 Metric PPS Plastic Grid and SS Netting X XX RH+T+Td+a+Tw+x+h Y YY Duct Mounting 10, 120 Deg C
HMP233-D-1-F-0-C-2-x-xx-y-yy-z-1-C-3-A Current Loop Metric PPS Plastic Grid and SS Netting X XX RH+T+Td+a+Tw+x+h Y YY Duct Mounting 10, 120 Deg C