Global Business Directory

Search for: Products & Services Company Name
 
 


Watlow Electric Manufacturing - Cartridge Heaters, Tubular, Radiant, Thermocouples, RTD Thermistor Company Profile
Watlow Electric Manufacturing - Cartridge Heaters, Tubular, Radiant, Thermocouples, RTD Thermistor
Private Ownership
12001 Lackland Rd
St. Louis, MO 63146 USA

Phone: 314.878.4600
Fax: 314.878.6814
Tollfree: 800.928.5692

www.watlow.com

Limit Control, Temperature, DIN Rail Mount, RTD
  • DIN Rail Mount
  • Sensor break protection
  • FM Limit control







    Control Mode Operator Interface Input Output Accuracy Power
    High or low limit, factory selectable LED indication of output status Thermocouple or platinum RTD available Electromechanical relay, 8A, Form C, SPDT Adjustable Set Point Calibration ±1% of span at 77° F ± 5° F 120V~ +10%/-15%, 50/60 Hz
    Manual or automatic reset on power loss Dial Scale calibrated to compensate for sensor non-linearities Thermocouple with automatic cold junction compensation 8A @ 240V~, @ 28V (dc), resistive Adjustable Set Point ± 3% of dial scale 230V~ +10%/-15%, 50/60 Hz
    Latching alarm with manual reset Integral set point dual temperature scale (F° and C°) Thermocouple may be isolated or grounded 275VA pilot duty rated at 240V~ Adjustable Set Point Span 540° C (1000° F) minimum 10VA maximum power
    Internal and/or customer supplied external reset switch Fixed Set Point, manufactured to specified value Thermocouple and RTS break protection de-energizes output ~ Fixed Set Point Calibration ±10° F/± 6° F of setting ~

  • Customize your results in the table below... Reset Table
    Filter Products : Sort Products :
          Input 1 - Controller  
          Input Range (C. ) 
          Limit Mode  
          Power Supply (V ) 
          First by     
          Then by     
       

    Showing 1 through 30 of 40 items   |   Next page
    Stock #
    Output 1, Controller
    Input 1 - Controller
    Input Range
    (C. )
    Limit Mode
    Power Supply
    (V )
    146-E-1-101-1 Electromechanical Relay, Form C, 8A 101 RTD -73 to 600 (100 ohms) High Limit, Manual reset on power loss 120
    146-E-2-101-2 Electromechanical Relay, Form C, 8A 101 RTD -73 to 600 (100 ohms) Low Limit, Manual reset on power loss 230...240 AC
    146-E-1-101-3 Electromechanical Relay, Form C, 8A 101 RTD -73 to 600 (100 ohms) High Limit, Automatic reset on power loss 120
    146-E-2-101-4 Electromechanical Relay, Form C, 8A 101 RTD -73 to 600 (100 ohms) Low Limit, Automatic reset on power loss 230...240 AC
    146-E-1-104-1 Electromechanical Relay, Form C, 8A 104 RTD -73 to 600 (1000 ohms) High Limit, Manual reset on power loss 120
    146-E-2-104-2 Electromechanical Relay, Form C, 8A 104 RTD -73 to 600 (1000 ohms) Low Limit, Manual reset on power loss 230...240 AC
    146-E-1-104-3 Electromechanical Relay, Form C, 8A 104 RTD -73 to 600 (1000 ohms) High Limit, Automatic reset on power loss 120
    146-E-2-104-4 Electromechanical Relay, Form C, 8A 104 RTD -73 to 600 (1000 ohms) Low Limit, Automatic reset on power loss 230...240 AC
    146-E-1-105-1 Electromechanical Relay, Form C, 8A 105 RTD 0 to 80 High Limit, Manual reset on power loss 120
    146-E-2-105-2 Electromechanical Relay, Form C, 8A 105 RTD 0 to 80 Low Limit, Manual reset on power loss 230...240 AC
    146-E-1-105-3 Electromechanical Relay, Form C, 8A 105 RTD 0 to 80 High Limit, Automatic reset on power loss 120
    146-E-2-105-4 Electromechanical Relay, Form C, 8A 105 RTD 0 to 80 Low Limit, Automatic reset on power loss 230...240 AC
    146-E-1-106-1 Electromechanical Relay, Form C, 8A 106 RTD Fixed at -155 High Limit, Manual reset on power loss 120
    146-E-2-106-2 Electromechanical Relay, Form C, 8A 106 RTD Fixed at -155 Low Limit, Manual reset on power loss 230...240 AC
    146-E-1-106-3 Electromechanical Relay, Form C, 8A 106 RTD Fixed at -155 High Limit, Automatic reset on power loss 120
    146-E-2-106-4 Electromechanical Relay, Form C, 8A 106 RTD Fixed at -155 Low Limit, Automatic reset on power loss 230...240 AC
    146-E-1-107-1 Electromechanical Relay, Form C, 8A 107 RTD Fixed at 350 High Limit, Manual reset on power loss 120
    146-E-2-107-2 Electromechanical Relay, Form C, 8A 107 RTD Fixed at 350 Low Limit, Manual reset on power loss 230...240 AC
    146-E-1-107-3 Electromechanical Relay, Form C, 8A 107 RTD Fixed at 350 High Limit, Automatic reset on power loss 120
    146-E-2-107-4 Electromechanical Relay, Form C, 8A 107 RTD Fixed at 350 Low Limit, Automatic reset on power loss 230...240 AC
    146-E-1-108-1 Electromechanical Relay, Form C, 8A 108 RTD Fixed at 110 High Limit, Manual reset on power loss 120
    146-E-2-108-2 Electromechanical Relay, Form C, 8A 108 RTD Fixed at 110 Low Limit, Manual reset on power loss 230...240 AC
    146-E-1-108-3 Electromechanical Relay, Form C, 8A 108 RTD Fixed at 110 High Limit, Automatic reset on power loss 120
    146-E-2-108-4 Electromechanical Relay, Form C, 8A 108 RTD Fixed at 110 Low Limit, Automatic reset on power loss 230...240 AC
    146-E-1-109-1 Electromechanical Relay, Form C, 8A 109 RTD Fixed at 150 High Limit, Manual reset on power loss 120
    146-E-2-109-2 Electromechanical Relay, Form C, 8A 109 RTD Fixed at 150 Low Limit, Manual reset on power loss 230...240 AC
    146-E-1-109-3 Electromechanical Relay, Form C, 8A 109 RTD Fixed at 150 High Limit, Automatic reset on power loss 120
    146-E-2-109-4 Electromechanical Relay, Form C, 8A 109 RTD Fixed at 150 Low Limit, Automatic reset on power loss 230...240 AC
    146-E-1-110-1 Electromechanical Relay, Form C, 8A 110 RTD Fixed at 120 High Limit, Manual reset on power loss 120
    146-E-2-110-2 Electromechanical Relay, Form C, 8A 110 RTD Fixed at 120 Low Limit, Manual reset on power loss 230...240 AC